Список продукции

Дизельные пожарные насосы
Электрический пожарный насос
Блок пожарных насосов
Передвижная насосная станция

Электрический вертикальный многоступенчатый насос XBD-DL

Расход: 1~100L/s

Напор: 0.2~2.6MPa

Диаметр отверстия: 40~200mm

Мощность: 1.5~220kW

Скорость вращения: 1450r/min

Рабочее давление: 2.5MPa

Если вы хотите получить больше информации о продукции, пожалуйста, свяжитесь с нами!

  • Описание
  • Конструкция
  • Применение
  • Технические параметры
Vertical Multistage Electric Fire Pump

XBD series fire pumps are a kind of new type fire products researched and developed in full compliance with the state issued-newly standard of GB6245-2006 "Fire pump", according to the end-user's practical needs and special using requirements. The inspection of the state fire equipment quality supervising center shows its all kinds of performance indexes are up to or over the standard's requirements and it earned the certificate for fire state products.

1. Application Scope
XBD series fire pumps are mainly used for the fixed fire hydrant system; automatic spraying fire system used by all sorts of organs, projects, high-floor buildings etc. and can be transferred with the clear water without solid grain under 100 or its equivalence, also be used for public-used water providing system for fire, living, production, construction and municipality.

2. Using Instruction

Before start:
1. Turning the clutch by hand, there should be no jammed phenomenon at the turner position.
2. Opening the inlet valve and the vent valve, letting the water fill into the pump's chamber, then closing the vent valve.
3. Clicking the switch of motor, and confirming whether the turning is right or not.

Running:
1. Fully opening the inlet valves, and closing the valves of the outlet pipe.
2. Connecting the power, Opening the valves of the outlet pipe and adjusting the needed working point when the turning velocity is normal.
3. Watching whether there exist abnormities or not, if yes, should the pump be stopped and inspected before re-running.

Stop:
1. After turning off the outlet valves one by one, shutting off the power.
2. Shutting off the inlet valves.
3. If the ambient temperature is below 0, some warm keeping measures should be adopted.

Модель

Расход(m3/h)

Напор (мПа)

Мощность (кВт)

Скорость (об./мин.)

Диаметр отверстия (mm)
XBD2.0/1.67-40DL 6 0.2 1.5 2900 40
XBD10.0/1.67-40L 7.2 1.0 7.5 2900 40
XBD2.0/5-50DL 18 0.5 3 2900 50
XBD4.0/5-50DL 18 0.4 4 2900 50
XBD7.8/5-50DL 18 0.78 7.5 2900 50
XBD10.2/5-50DL 21.6 1.02 11 2900 50
XBD3.0/10-65DL 43.2 0.3 5.5 2900 65
XBD7.0/10-65DL 36 0.7 15 2900 65
XBD6.0/15-80DL 54 0.6 15 2900 80
XBD12.0/15-80DL 54 1.20 30 2900 80
XBD9.3/20-100DL 72 0.93 37 2900 100
XBD16.0/20-100DL 72 1.6 55 2900 100
XBD8.0/25-100DL 90 0.8 37 2900 100
XBD14.0/25-100DL 108 1.4 75 2900 100
XBD4.0/30-125DL 108 0.4 18.5 2900 125
XBD8.0/35-125DL 108 0.6 45 2900 125
XBD6.0/40-150DL 144 0.6 37 2900 150
XBD14.0/40-150DL 144 1.4 75 2900 150
XBD12.2/45-125DL 162 1.22 90 2900 150
XBD17.5/50-150DL 194 1.75 132 2900 150
XBD3.8/80-200DL 288 0.38 55 2900 200
XBD12.0/80-200DL 180 1.20 160 2900 200

ДЛЯ ПОЛУЧЕНИЯ БОЛЕЕ ДЕТАЛЬНОЙ СПЕЦИФИКАЦИИ, ПОЖАЛУЙСТА, СВЯЖИТЕСЬ С НАМИ